Identification of Priority Air Pollutants in Confined Spaces
https://doi.org/10.35627/2219-5238/2021-29-9-62-68
Abstract
Introduction: Owing to the rapid development of digital technologies, most people nowadays are working indoors while using no machinery or equipment and being unexposed to volatile industrial chemicals. Yet, people staying inside for too long often complain of poor indoor air quality and microclimate.
Our objective was to study air pollutants in a simulation experiment with continuous human occupancy inside unventilated confined spaces.
Materials and methods: Up-to-date sensitive analytical techniques, such as photoionization, laser nephelometry, gas-phase chemiluminescence, spectrophotometry, high-performance liquid chromatography with diode array detection (HPLCDAD) and gas chromatography–mass spectrometry (GC-MS), were used to determine indoor air pollutants.
Results: We compared changes in airborne concentrations of nitrogen oxides, prop-2-enenitrile, acetaldehyde, benzene, but- 2-enal, airborne particulate matter (PM2,5 and PM10), methylbenzene, 2-methylbuta-1,3-diene, formaldehyde, prop-2-en- 1-al, carbon oxide and dioxide following 1.5, 3.0, and 4.5 hours of stay of volunteers in a 15.9 m2 room ((4.0 m2 per person; a 2.55 m ceiling height) against background levels. The established human occupancy-related priority pollutants included acetaldehyde, formaldehyde, prop-2-en-1-al, and carbon dioxide. Laboratory testing showed the presence of 83 volatile and semivolatile organic chemicals in the unventilated room, among which aromatic hydrocarbons, esters and aldehydes prevailed.
Conclusion: Our findings could be useful for designing ventilation systems in confined spaces and optimizing the workbreak schedule during the working hours.
About the Authors
O. L. MarkovaRussian Federation
Olga L. Markova, Cand. Sci. (Biol.), Senior Researcher, Department of Health Risk Analysis
4 2nd Sovetskaya Street, Saint Petersburg, 191036, Russian Federation
E. V. Zaritskaya
Russian Federation
Ekaterina V. Zaritskaya, Head of the Department for Laboratory Testing
4 2nd Sovetskaya Street, Saint Petersburg, 191036, Russian Federation
M. N. Kir’yanova
Russian Federation
Marina N. Kir’yanova, Cand. Sci. (Med.), Senior Researcher, Department of Health Risk Analysis
4 2nd Sovetskaya Street, Saint Petersburg, 191036, Russian Federation
E. V. Ivanova
Russian Federation
Elena V. Ivanova, Research Assistant, Department of Health Risk Analysis
4 2nd Sovetskaya Street, Saint Petersburg, 191036, Russian Federation
References
1. Dudarev AA, Sorokin GA. Pressing problems of labor hygiene and occupational pathology among office workers. Meditsina Truda i Promyshlennaya Ekologiya. 2012;(4):1–8. (In Russ.)
2. Kir’yanova MN, Markova OL, Ivanova EV. [Urgent problems of air quality in office rooms.] In: Proceedings of the All-Russian Scientific and Practical Conference with International Participation “Preventive Medicine–2017”, St. Petersburg, December 6–7, 2017. St. Petersburg: I.I. Mechnikov Northwestern State Medical University Publ., 2017:9-14. (In Russ.)
3. Kriyt VE, Sladkova YuN, Badaeva EA, Smirnov VV, Zaritskaya EV. On the issue of hygienic requirements for air quality of enclosed spaces at housing construction projects at the stage of commissioning. Gigiena i Sanitariya. 2019;98(6):608–612. (In Russ.) doi: 10.18821/0016-9900-2019-98-6-608-612
4. Zaretskaya EV, Sladkova YuN, Smirnov VV. Indoor air: actual problems, health effects, preventive measures. Sanitarnyy Vrach. 2018;(4):49–54. (In Russ.)
5. Ivanova EV, Markova OL, Kir’yanova MN. Peculiarities of air environment formation in modern residential buildings. Zdorov’e Naseleniya i Sreda Obitaniya. 2019;(10(319)):50–53. (In Russ.) doi: 10.35627/2219-5238/2019-319-10-50-53
6. Malysheva AG. [Volatile organic compounds in indoor air of residential and public buildings.] Gigiena i Sanitariya. 1999;(1):43–46. (In Russ.)
7. Lebedeva NV, Furman VD, Kislitsin VA, et al. Impact of building and finishing materials and new furniture on the occurrence of respiratory diseases in children. Gigiena i Sanitariya. 2004;(4):49. (In Russ.)
8. Tang X, Misztal PK, Nazaroff WW, Goldstein AH. Volatile organic compound emissions from humans indoors. Environ Sci Technol. 2016;50(23):12686–12694. doi: 10.1021/acs.est.6b04415
9. Rossignol S, Rio C, Ustache A, et al. The use of a housecleaning product in an indoor environment leading to oxygenated polar compounds and SOA formation: Gas and particulate phase chemical characterization. Atmos Environ. 2013;75:196–205. doi: 10.1016/j.atmosenv.2013.03.045
10. Liu Y, Misztal PK, Xiong J, et al. Characterizing sources and emissions of volatile organic compounds in a northern California residence using space- and time-resolved measurements. Indoor Air. 2019;29(4):630–644. doi: 10.1111/ina.12562
11. Kvashnin IM, Gurin II. [On the issue of air exchange regulation as regards СО2 concentration in outdoor and indoor air.] АVOK: Ventilyatsiya, Otoplenie, Konditsionirovanie Vozdukha, Teplosnabzhenie i Stroitel’naya Teplofizika. 2008;(5):34–39. (In Russ.)
12. Naumov AL, Kapko DV. [СО2: Ventilation system efficiency criterion.] АVOK: Ventilyatsiya, Otoplenie, Konditsionirovanie Vozdukha, Teplosnabzhenie i Stroitel’naya Teplofizika. 2015;(1):12–21. (In Russ.)
13. [СО2 monitoring and indoor air quality.] АVOK: Ventilyatsiya, Otoplenie, Konditsionirovanie Vozdukha, Teplosnabzhenie i Stroitel’naya Teplofizika. 2021;(4):66–71. (In Russ.)
14. Laverge J, Delghust M, Janssens A. Carbon dioxide concentrations and humidity levels measured in Belgian standard and low energy dwellings with common ventilation strategies. Int J Vent. 2015;14(2):165–180. doi: 10.1080/14733315.2015.11684078
15. Gubernskiy YuD, Kalinina NV, Gaponova EB, Banin IM. Rationale for the permissible level of carbon dioxide in indoor air in residential and public buildings with the permanent human presence. Gigiena i Sanitariya. 2014;(93(6)):37–41. (In Russ.)
16. Lefebvre MA, Meuling WJA, Engel R, et al. Consumer inhalation exposure to formaldehyde from the use of personal care products/cosmetics. Regul Toxicol Pharmacol. 2012;63(1):171–176. doi: 10.1016/j.yrtph.2012.02.011
17. Gubernskiy YuD, Kalinina NV. [Hygienic characteristics of chemical risk factors in a residential environment.] Gigiena i Sanitariya. 2001;94(1):21–24. (In Russ.)
18. Nikiforova NV, Kokoulina AA, Zagorodnov SYu. Evaluation of indoor air pollution with formaldehyde in conditions of the use of constructional and finish materials with polymeric components. Gigiena i Sanitariya. 2016;95(1):28–32. (In Russ.) doi: 10.18821/0016-9900-2016-95-1-28-32
19. Nikiforova NV, May IV. To the problem of rating the migration of formaldehyde from polymer containing building, finishing materials and furniture. Gigiena i Sanitariya. 2018;97(1):43–49. (In Russ.) doi: 10.18821/0016-9900-2018-97-1-43-49
20. Yeoman AM, Shaw M, Carslaw N, Murrells T, Passant N, Lewis AC. Simplified speciation and atmospheric volatile organic compound emission rates from non-aerosol personal care products. Indoor Air. 2020;30(3):459–472. doi: 10.1111/ina.12652
21. Sarwar G, Olson DA, Corsi RL, Weschler CJ. Indoor fine particles: the role of terpene emissions from consumer products. J Air Waste Manag Assoc. 2004;54(3):367–377. doi: 10.1080/10473289.2004.10470910
22. Singer BC, Destaillats H, Hodgson AT, Nazaroff WW. Cleaning products and air fresheners: emissions and resulting concentrations of glycol ethers and terpenoids. Indoor Air. 2006;16(3):179–191. doi: 10.1111/j.1600-0668.2005.00414.x
23. Lejbovich LI. Рurification of internal air of buildings from organic products of human metabolism. Modern Engineering and Innovative Technologies. 2019;1(07-01):4-7. (In Russ.) doi: 10.30890/2567-5273.2019-07-01-001
24. Steinemann AC. Fragranced consumer products and undisclosed ingredients. Environ Impact Assess Rev. 2009;29(1):32–38. doi: 10.1016/j.eiar.2008.05.002
Review
For citations:
Markova O.L., Zaritskaya E.V., Kir’yanova M.N., Ivanova E.V. Identification of Priority Air Pollutants in Confined Spaces. Public Health and Life Environment – PH&LE. 2021;29(9):62-68. (In Russ.) https://doi.org/10.35627/2219-5238/2021-29-9-62-68